Hainwise Medical Technology Co.,Ltd
- E-mail: info@hainwise.com
Hainwise Medical Technology Co.,Ltd
Key Benefits:
Deliverability:Low tip entry profile enables tight tracking to the wire. Robust, flexible shaft design facilitates successful navigation in tortuous vessels.
Predictability:Balloon material and design allow for shape retention at rated burst pressure. Focal pressure is exerted on the lesion for controlled, targeted treatment.
Procedural efficiency:Balloon material and wall thickness permit reliable balloon rewrap into the sheath. Rapid deflation time contributes to reduced occlusion time.
The X-Ace™ Neuro High Pressure Balloon represents a technological advancement in neurovascular intervention, combining ultra-low profile delivery with controlled high-pressure dilation capability. Engineered specifically for the anatomical and physiological demands of cerebral and peripheral neurovascular systems, this balloon catheter delivers precise, predictable, and efficient treatment of atherosclerotic lesions, vasospasm, and vessel preparation prior to stent placement.
Ultra-Low Tip Entry Profile: Proprietary distal tip design minimizes crossing profile while maintaining secure wire tracking, facilitating access through highly stenotic and tortuous neurovascular pathways.
Robust Flexible Shaft Construction: Multi-layer composite shaft architecture balances pushability and flexibility, enabling successful navigation through complex cervical and intracranial anatomy without compromising device integrity or control.
Advanced Balloon Material Engineering: Proprietary semi-compliant polymer matrix maintains predetermined cylindrical shape at rated burst pressures (RBP), ensuring uniform radial force distribution and minimizing "dog-boning" effects.
Focal Pressure Application: Precision balloon design concentrates therapeutic pressure specifically at the lesion site, enabling controlled vessel expansion while preserving adjacent healthy endothelium and minimizing vessel trauma.
Superior Rewrap Characteristics: Controlled wall thickness and material memory enable consistent, low-profile balloon folding after deflation, facilitating smooth withdrawal through microcatheters or guide sheaths.
Rapid Deflation Dynamics: Engineered deflation channel geometry reduces occlusion time by achieving complete balloon deflation in <3 seconds (typical), minimizing cerebral ischemia duration during critical neurovascular procedures.
Intracranial Atherosclerotic Disease (ICAD): Controlled dilation of symptomatic intracranial stenosis
Vasospasm Management: Post-subarachnoid hemorrhage vasospasm treatment with controlled pressure application
Stent Preparation: Vessel pre-dilation prior to neurovascular stent deployment
Mechanical Thrombectomy Adjunct: Vessel dilation following clot extraction in resistant cases
Carotid Artery Angioplasty: Focal lesion treatment in cervical carotid segments
Vertebral Artery Interventions: Precise dilation in posterior circulation anatomy
Resistant Lesion Crossing: Facilitates device delivery through calcified or fibrotic lesions
Pediatric Vascular Conditions: Available in smaller diameters for pediatric neurovascular applications
X - Ace™Neuro high pressure Ballon | Balloon Diameter (mm) | 4, 5, 6, 7, 8, 9, 10,12 |
| Balloon length (mm) | 20, 30, 40, 60, 80, 100, | |
| Nominal pressure (atm) | 12, 9, 8, 7 | |
| Rated burst pressure (atm) | 24, 23, 20, 19, 18, 16, 14, 12 | |
| Recommended introducer sheath (Fr) | 6, 7, 8 | |
| Catheter working length (cm) | 50, 75, 135 |
Related Products
OEM cooperation available
Full range of guide wire production lines
We already have the most advanced OEM/ODM solutions in the intervention medical guidewires and catheters product range, which we can bring to customers worldwide.
Leave Your Message
Please leave your information in order to download our files and get in touch with you