Hainwise Medical Technology Co.,Ltd

Products
Home > Products>Saturn™ PTFE Guidewire ( Standard Type )

Saturn™ PTFE Guidewire ( Standard Type )

Key Benefits:   

  • Low-Friction Surface Coating

  • Minimizes Vessel Trauma     

  • Biocompatible and Chemically Inert

  • Superior Pushability and Torque Response

  • Comprehensive Range of Diameters and Lengths



Saturn™ PTFE Guidewire (Standard Type): Precision Performance for Enhanced Procedural Efficiency


Hainwise Urology presents the Saturn™ PTFE Guidewire (Standard Type)—a reliable and versatile guidewire engineered to deliver exceptional performance across a wide spectrum of urological and endovascular procedures. With its advanced low-friction PTFE coating and balanced mechanical design, the Saturn™ guidewire provides superior pushability, precise torque control, and atraumatic navigation, making it an indispensable tool for clinicians seeking efficiency and safety in complex anatomical pathways.


Core Features & Technical Advantages



1.Low-Friction Surface Coating:The advanced PTFE coating ensures minimal surface resistance, enabling smooth and effortless advancement through tortuous vessels and strictured urinary tracts without compromising procedural control.

2.Minimized Vessel Trauma:Designed with a soft, atraumatic tip and an optimized transition zone to reduce the risk of endothelial injury, perforation, or mucosal damage during navigation and device exchange.

3.Biocompatible and Chemically Inert:Constructed from fully biocompatible materials that are chemically inert, ensuring compatibility with various contrast agents, medications, and bodily fluids while minimizing the risk of adverse tissue reactions.

4.Superior Pushability and Torque Response:A balanced core design delivers excellent one-to-one torque transmission and reliable forward pushability, allowing precise directional control even in challenging anatomical configurations.

5.Comprehensive Range of Diameters and Lengths:Available in multiple diameters (0.018" to 0.038") and extended working lengths (up to 300 cm), offering tailored solutions for diverse clinical scenarios—from pediatric interventions to complex renal access.



Clinical Applications



  • Ureteral Access and Stent Placement:

Ideal for initial ureteral cannulation, stent positioning, and exchange in both straightforward and anatomically challenging cases.

  • Endovascular Diagnostics and Interventions:

Suitable for vascular access, selective catheterization, and as a platform for device delivery in peripheral and renal artery procedures.

  • Percutaneous Nephrostomy and Nephrolithotomy:

Provides reliable guidance during renal puncture, tract dilation, and sheath placement in PCNL and drainage procedures.

  • Pediatric and Small-Vessel Applications:

Smaller diameter options allow safe use in pediatric urology and narrow vascular pathways with maintained performance.

  • Interventional Radiology and Cross-Specialty Use:

Versatile enough for biliary, drainage, and other non-vascular interventions requiring precise wire-guided access.



Model
Ref.
(Straight Tip)
Model
Ref.
(J Tip)
Outer
Diameter
(inch)
Length
(cm)
Model
Ref.
(Straight Tip)
   Model
   Ref.
   (JTip)
Outer
Diameter
(inch)
Length
(cm)
  PW-21080NSPW-21080NJ0.021   80   PW-32080NSPW-32080NJ  0.032   80 
  PW-21110NSPW-21110NJ0.021   110   PW-32110NSPW-32110NJ  0.032   110 
  PW-21150NSPW-21150NJ0.021   150   PW-32150NSPW-32150NJ  0.032   150 
  PW-21180NSPW-21180NJ0.021   180   PW-32180NSPW-32180NJ  0.032   180 
  PW-21200NSPW-21200NJ0.021   200   PW-32200NSPW-32200NJ  0.032   200 
  PW-21260NSPW-21260NJ0.021   260   PW-32260NSPW-32260NJ  0.032   260 
  PW-21300NSPW-21300NJ0.021   300   PW-32300NSPW-32300NJ  0.032   300 
  PW-25080NSPW-25080NJ0.025   80   PW-35080NSPW-35080NJ  0.035   80 
  PW-25110NSPW-25110NJ0.025   110   PW-35110NSPW-35110NJ  0.035   110 
  PW-25150NSPW-25150NJ0.025   150   PW-35150NSPW-35150NJ  0.035   150 
  PW-25180NSPW-25180NJ0.025   180   PW-35180NSPW-35180NJ  0.035   180 
  PW-25200NSPW-25200NJ0.025   200   PW-35200NSPW-35200NJ  0.035   200 
  PW-25260NSPW-25260NJ0.025   260   PW-35260NSPW-35260NJ  0.035   260 
  PW-25300NSPW-25300NJ0.025   300   PW-35300NSPW-35300NJ  0.035   300 
  PW-28080NSPW-28080NJ0.028   80   PW-38080NSPW-38080NJ  0.038   80 
  PW-28110NSPW-28110NJ0.028   110   PW-38110NSPW-38110NJ  0.038   110 
  PW-28150NSPW-28150NJ0.028   150   PW-38150NSPW-38150NJ  0.038   150 
  PW-28180NSPW-28180NJ0.028   180   PW-38180NSPW-38180NJ  0.038   180 
  PW-28200NSPW-28200NJ0.028   200   PW-38200NSPW-38200NJ  0.038   200 
  PW-28260NSPW-28260NJ0.028   260   PW-38260NSPW-38260NJ  0.038   260 
  PW-28300NSPW-28300NJ0.028   300   PW-38300NSPW-38300NJ  0.038   300 



Related Products

OEM cooperation available

Full range of guide wire production lines

We already have the most advanced OEM/ODM solutions in the intervention medical guidewires and catheters product range, which we can bring to customers worldwide.

Leave Your Message